Cold aisle containment at DC2SCALE PAR3 datacenter, featuring APC racks and Inrow cooling systems for optimized airflow management
Inovel Parc Nord - Vélizy-Villacoublay

dc2scale Paris-Vélizy PAR3

With more than 8 operators present, the dc2scale PAR3 datacenter offers exceptional connectivity and Tier 3 level electrical and climate redundancy.
With a capacity of 200 racks spread over a total area of approximately 1500 m², this facility can accommodate high-density critical infrastructures with flexible power up to 22 kW per bay in Air Cooling and up to 150 kW in Direct Liquid Cooling.

Space

1500m² total surface area

Capacity

200 racks

Electricity

1,5 MVA electrical capacity

Connectivity

+8 present operators

Flexibility

Our data center oriented towards flexibility

Thanks to a well-managed end-to-end design, PAR3 stands out for its ability to meet a wide range of demands in terms of capacity, density, and also resilience.

Cold aisle containment at DC2SCALE PAR3 datacenter, featuring APC racks and Inrow cooling systems for optimized airflow management
A close-up shot of yellow and green fiber cables plugged into a data center network equipment (Cisco). The cables are bright and colorful, standing out against the grey server. The background is out of focus.
Black and grey server racks with an APC logo are aligned in a long corridor in a data center. The perspective is from a low angle. The focus is on the front racks and the rest of the corridor is blurry.
Resilient

Technical excellence & redundancy

We guarantee optimal redundancy at the electrical level (N+1 + N) and climatic (2N): designed, built, and maintained by experts in compliance with the strictest industry standards. Our chilled water cooling system uses indirect free cooling in a closed loop for maximum energy efficiency.

Datacenter Design Tier3

Multiple paths for electricity and the network, with N+2 redundant cooling to ensure stable conditions under all circumstances.

High availability food

PAR3 has two electrical connections of 1.5 MW each with N+1 inverters and 72-hour fuel autonomy at full load.

Black and white shot of a data center aisle. The symmetrical composition with the corridor in the middle emphasizes the long line of server racks on each side. The aisle is brightly lit by a luminous ceiling, contrasting with the dark racks.
Image
But always cost-efficient

Cooling and energy efficiency

Thanks to our chilled water cooling system with indirect free cooling, PAR3 achieves exceptional energy efficiency. The closed-loop dry cooling technology allows for optimizing performance while reducing environmental impact.

Advanced Indirect Freecooling

Our system uses outdoor air for cooling 86% of the time, achieving an average PUE of 1.35.

No water consumption

We have a WUE (Water Usage Efficiency) equal to 0L/kWh.

Compare our data centers – Vélizy PAR3

Discover the technical characteristics

Access all the technical information of our data centers: power, connectivity, redundancy, and energy efficiency. Compare their configurations and download detailed sheets to accurately evaluate each site.

PAR2 Datacenter illustration
Paris-Vélizy

Discover the Campus

With a total of 4 sites, our interconnected Paris-Vélizy campus offers complementary and integrated sites to allow you efficient scalability.

Ready to deploy?

Build the infrastructure of tomorrow.

Host your applications where performance, control, and energy efficiency are not options.

Inside view of a datacenter cold corridor in the DC2SCALE PAR2 Paris-Vélizy Datacenter