Marseille Prado

dc2scale Marseille MRS1

The MRS1 data center of DC2SCALE offers an ideal nearby colocation for businesses in the Southern region. Designed according to Tier 3 standards, it features dual power supply and redundant cooling, ensuring high availability and 24/7 security. Its neutral and efficient connectivity makes it a strategic anchor point for your critical infrastructures, at the crossroads of major Mediterranean interconnections.

Space

800m² total surface

Capacity

60 bay capacity

Electricity

1250 kVA electrical capacity

Density

Flexible and high-density colocation, designed for HPC

The MRS1 datacenter is HPC-ready, capable of hosting high-density loads thanks to suitable electrical and cooling infrastructure. Its flexible and scalable colocation meets both high-performance computing needs and customized IT deployments, directly in the heart of Prado in the Phocaean city.

Inside view of a datacenter cold corridor in the DC2SCALE PAR2 Paris-Vélizy Datacenter
enter view of a APC by Schneider datacenter cold-corridor in dc2scale-par2-paris-velizy
Many yellow fiber cables connected to a switch in rack dc2scale par2 velizy
Resilient

Resonance & performance

We guarantee ideal electrical redundancy (N+1): designed, built, and maintained by experts in compliance with industry standards. From a cooling perspective, our air conditioning cabinets (CRACs) each operate with 2 redundant cooling circuits.

Data center design Tier 3

Separate paths for electricity and the network, with adjustable cooling to ensure stable conditions under all circumstances.

Uninterrupted power supply

MRS1 has a generator

Zoom on apc modular power dc2scale par2 velizy
A wide-angle interior shot of a data center in Vélizy-Villacoublay, Île-de-France, France. On the left, rows of black server racks with perforated doors line the aisle. On the right, a series of large, dark grey Stulz Computer Room Air Conditioners (CRACs) are visible, providing essential cooling for the data center equipment. The floor is composed of white square tiles, and the ceiling is painted a distinctive dark blue, from which fluorescent lights are suspended, illuminating the entire space. The aisle is empty, highlighting the organized and functional environment of the facility.
Cost-efficient

Cooling & efficiency

Thanks to intelligent and optimized cooling management, MRS1 significantly reduces its energy consumption. Less electricity used for air conditioning means not only a reduced environmental impact but also lower operational costs, savings directly passed on to our customers.

Direct Free-Cooling

By directly using air for cooling, we achieve a PUE of 1.15 at this site.

No water consumption

We have a WUE (Water Use Efficiency) equal to 0.

Compare our data centers – Marseille MRS1

Discover the technical specifications

Access all the technical information of our data centers: power, connectivity, redundancy, and energy efficiency. Compare their configurations and download detailed sheets to accurately evaluate each site.